Home » Products » Diesel Generator Set » 160kVA / 180kVA / 200kVA Diesel Generator Set

160kVA / 180kVA / 200kVA Diesel Generator Set

160kVA / 180kVA / 200kVA Diesel Generator Set
160kVA / 180kVA / 200kVA Diesel Generator Set
Send Inquiry
Product Code : 01
Price And Quantity
  • Minimum Order Quantity
  • 1
  • Unit of Measure
  • Set/Sets
  • Price
  • 755000 to 955000 INR
Product Specifications
  • Fuel Tank Capacity
  • 300 Liter (L)
  • Dimension(L*W*H)
  • 4300*1400*1800 Millimeter (mm)
  • Engine Type
  • 4-stroke
  • Fuel Consumption
  • 7.2 Liter/Hour (L/hr)
  • Product Type
  • Diesel Generator
  • Rated Voltage
  • 430V Volt (V)
  • Starting Type
  • Electric Start
  • Rated Frequency
  • 50 Hertz (HZ)
  • Color
  • Red
  • Cooling System
  • water cooled
  • Noise Level
  • <75 db
  • Phase
  • Three Phase
  • Speed
  • 1500 RPM
  • Weight
  • apro.2750 Kilograms (kg)
  • Warranty
  • 2
Product Description

Technical Specifications :

Genset Rating (kVA)

160

180

200

Power Rating (kW)

128

144

160

No. of Phases

3 Phase

3 Phase

3 Phase

Output Voltage (V)

415V

415V

415V

Power Factor (lagging)

0.8

0.8

0.8

Current (A) (1phase / 3 phase)

223

251

278

Frequency (Hz) RPM

50/1500

50/1500

50/1500

Governing Class

G2 as per ISO 8528 part V

Starting system

24 V DC Electrical

24 V DC Electrical

24 V DC Electrical

Fuel tank capacity (lit)

300

400

400

Genset dimensions (L x W x H) (mm) approx

3790x1300x1800

4300x1400x1800

4300x1400x1800

Genset weight (kg)

2350

2750

2800

Engine Specifications :

Make

Mahindra mPower

Model

mPower 61995G

mPower 62235G

mPower 62485G

Power Output (HP)

199

223

248

Aspiration

TCA

TCA

TCA

No. of cylinders

6

6

6

Bore x Stroke (mm)

105X137

105X137

105X137

Displacement (cc)

7.2

7.2

7.2

Fuel consumption @ 75% load (lit/hr)

27.8

27.8

33.3

Fuel consumption @ 100% load (lit/hr)

36.7

38.2

40.8

Lube oil specification

15W40 API CI4+

15W40 API CI4+

15W40 API CI4+

Total lube oil system capacity (liter)

20.2

20.2

20.2

Lube oil consumption (lit/hr)°

0.1% of Fuel Consumption

Lube oil change period (hrs.)

500 hrs for oil change

Radiator coolant capacity (liters)

25

24

24

Alternator Specifications

Make

Mahindra Powerol

Enclosure Type

IP23

IP23

IP23

Voltage regulation

+1%

+1%

+1%

Class of insulation

Class H

Class H

Class H

Maximum Unbalanced Load across Phases

25%

25%

25%

Notes :

  • Above specifications are subject to change without prior notice due to continuous product improvement
  • All Engines & alternators conform to respective IS standards
  • All the genset specifications conform to ISO 8528 Standard
  • height without sliencer
  • Fuel- High speed Diesel (HSO IS 1460 : 2005)
  • Considering 0.845 specific gravity of diesel, 5% tolerance
  • $Considering 0.89 specific gravity of oil.
  • All specifications are at standard NTP operating conditions
  • Engine power output 110% load.
Trade Information
  • FOB Port
  • mumbai
  • Payment Terms
  • Cheque, Cash in Advance (CID), Cash Advance (CA), Cash on Delivery (COD), Cash Against Delivery (CAD)
  • Main Domestic Market
  • Maharashtra

JALARAM GENERATOR SERVICES
X


Back to top
JALARAM GENERATOR SERVICES All Rights Reserved.(Terms of Use)